Leica ultramicrotome em uc7 user manual

Cut each block carefully and maintain critical diagnostic detail. Ultramicrotome and cryoultramicrotome neurophotonics. A leica em uc7 ultramicrotome was used to obtained slices at a nominal 70 nm thickness, which were then placed on carbon film tem grids. Easy download of user, sample, knife and storage parameters, via usb. The customer must check the condition of thesystem upon delivery and file a damage report with the shipping company ifthe equipment is damaged. We have 1 leica em fc7 manual available for free pdf download. Ultramicrotome leica em uc7 rt for preparation of semi and ultrathin sections, as well as perfect, smooth surfaces of biological and industrial samples for tem and sem analysis leica, germany high performance liquid chromatograph lc20ad shimadzu, japan gas chromatograph gc2010 plus shimadzu, japan. Ccmr operates worldclass electron microscopes in duffield hall, bard hall, and the clarkpsb complex. Leica uc7 ultramicrotome microscopy and imaging center. View online or download leica em fc7 operating manual.

Video tour learn more about the leica em uc7 ultramicrotome. Tetrahydrobenzimidazole tmq0153 triggers apoptosis. Data transfer for reporting user, specimen, knife and storage parameters provides an electronic. The leica em uc7 ultramicrotome is delivered properly packed and in the semiassembled state. We specialize in the sales, service and repair of sorvall, sorvalldupont and sorvallrmc microtomes and gkm knife makers. The microscopy and imaging center is a core user facility supported by the office of the vice president for research. Freeze fracture system leica em baf060 with vacuum cryo transfer system leica em vct100. Basic em categories are below, with unique capabilities noted click on the instrument name below for more information. Avoiding the artifactcausing conditions of manual sectioning and manipulation due to integrated direct sectionribbon collection. State of the art cryoultramicrotome for making frozen sections of polymers and other samples difficult to section at room temperatures.

Expedited largevolume 3d sem workflows for comparative. Leica ultracut uct ultramicrotome university imaging centers. Leica s mseries of rangefinder cameras are marvels of mechanical engineering and provide the photographer with rich and sometimes complex functionality. For perfect sectioning at room temperature and cryo ultramicrotome leica em uc7. All control functions are activated by touching the control monitor screen, or by mouse, or by using the digital controller.

The leica em fc7 and leica em crion ionizer controls are both integrated with the leica em uc7 control unit to provide easier operation and more workspace. Leica rotary microtomes give skilled microtomists the precision, control and comfort they need to get the best from every block. It uses a knife of diamond or glass to make cuts of 100 nm or less. Particular attention must be paid to the aspect of safety. The temperature will be kept during the sectioning process. New standard in ultramicrotomy combining ergonomic design and innovative technology the leica em uc7 sets new standards in ultramicrotomy. Microtome service company mts is founded on giving honest value for our products and services. The rm2235 rotary microtome is perfectly suited for those who expect precision sectioning and appreciate the feel and extra measure of control during manual sectioning. Leica em uc7fc7 ultramicrotome for room temperature and. Tissue blocks were sectioned with a leica em uc7 ultramicrotome leica, heerbrugg, switzerland equipped with a glass knife to reveal the underlying tissue and trimmed with an injector blade to remove excess resin fig. The sections were mounted on pieces of silicon substrate. Leica em uc7 the leica em uc7 prepares excellent quality.

Standard operating procedure for ultramicrotome careful sample preparation is critical to obtain good results. So its always useful to have an instruction manual available, just in case one needs to look up some camera or handling detail. The mic is staffed by research scientists with expertise in transmission electron microscopy, scanning electron microscopy, light microscopy, and supporting instruments. Fully digital, so samples can be scanned simply be viewing a computer screen. The sections are stained with 1% toluidine blue in 1% borax and inspected with a brightfield light microscope to verify fixation quality and the desired region of interest. Before quickly cooling down for trimming and sectioning, the cryochamber has to be unpacked, mounted on the em uc7 and connected to the ultracut uc7 cu. The ultramicrotome leica em uc7 provides easy preparation of semi and ultrathin sections as well as. Aug 29, 2017 the ultramicrotome is an instrument commonly used to prepare tem samples. The eucentric movement of the viewing system allows examination of sections even with lowered water level as with e. Post a free request for proposal for a leica em uc6 ultramicrotome microtome and get quotes from our gold service dealers. Sectioning of aluminum with ultramicrotome leica em uc7. It is advisable for the user to be trained in the useof the ultramicrotome. Ultrathin sections 7090 nm were obtained with ultramicrotome, em uc7 leica, germany.

It offers a range of outstanding features and benefits of use for the ultramicrotomist, whether highly skilled or absolute beginners. Leica ultracut em uct leica ultracut em uc7 cryochamber. The ultramicrotome leica em uc7 provides easy preparation of semi and ultrathin sections as well as perfect, smooth surfaces of biological and industrial samples for tem, sem, afm and lm examination new standard in ultramicrotomy combining ergonomic design and innovative technology the ultramicrotome leica em uc7 sets new standards in ultramicrotomy. This is particularly important for viewing low contrast samples, and is convenient. Page 39 thus, parts of the cooling element of the sample holder are placed into ln which facilitates cooling down the sample at a minimum of 170. Leica em uc7 ultramicortome provide easy preparation of semi and ultrathin sectins as well as perfect, smooth surfaces of biological and industrial samples for tem, sem, afm and lm examination. This user manual must be retained for future reference. The sections were then contrasted with a 2% aqueous solution of uranyl acetate for 10. The onepiece, protective housing provides long product life and the compact base features a wraparound, magnetized waste tray for spacesaving convenience. In general, tem samples must be less than 100 nm thick and afm requires a flat, smooth surface. Ultramicrotome, phased testing and adjustment of all components and. Leica histocore biocut manual rotary microtome wanted. Abstract plasmodesmata pd are nanometric 20 nm wide membrane lined pores encased in the cell walls of the adjacent plant cells. Nov 16, 2010 the ultramicrotome leica em uc7 provides easy preparation of semi and ultrathin sections as well as perfect, smooth surfaces of biological and industrial samples for tem, sem, afm and lm examination.

Consistently high quality sections the artos 3d ultramicrotome is able to deliver reproducible, high quality sections rapidly by. This user manual describes commissioning of the leica em uc7. It is used for semi and ultrathin cryosectioning of biological and industrial samples. The colour monitor displays bright, user friendly, control icons logically and clearly located around central video image display panel. For the scientist in need of advanced microscopy, the mic is a vertically integrated facility that provides a variety of services designed to move each project.

Leica em uc7 ultramicrotome from leica microsystems europe. Refurbished leica em uc6 ultramicrotome microtome for sale. The leica em uc6 ultramicrotome offers a range of outstanding features and benefits of use from the absolute beginner to the skilled ultramicrotomist. Leica em ice high pressure freezer microscopy and imaging. Service and operating staff must familiarize themselves with all components of the system before commissioning. Combining ergonomic design and innovative technology the ultramicrotome leica em uc7 sets new standards in ultramicrotomy. Serial sections with thickness of 45 nm were cut using an ultramicrotome em uc7. Jul 14, 2014 the ultramicrotome leica em uc7 provides easy preparation of semi and ultrathin sections as well as perfect, smooth surfaces of biological and industrial samples for tem, sem, afm and lm examination. This user manual describes commissioning of the leica em uc7ultramicrotome, phased testing and adjustment of all components andmovement sequences, and. Electron microscopy, transmission electron microscopy, stem. Biological sample preparation centre for advanced microscopy. Document about evinrude icommand manual is available on print and digital edition. Leica em fc7 mounted on ultracut uc7 with advanced touch screen control unit instrument function operation of the em fc7 is performed via the control unit of the ultracut uc7. Operating procedure for leica uct ultramicrotome room temperature conventional sectioning ultramicrotomy.

Sample dimensions should preferably be leica em uc6 operation manual for rt sectioning or the fc6. The reichertleica ultracut s ultramicrotome is designed for extremely precise cutting, and achieves consistent high quality ultra thin sections for electron microscopy, or semithin sections for light microscopy. Annular darkfield adf scanning transmission electron microscopy stem imaging of the residues was. They allow the cells to exchange all types of molecules ranging from nutrients like sugar, hormones, to rnas and various proteins. It provides easy preparation of semi and ultrathin sections as well as perfect, smooth surfaces of biological and industrial samples for tem, sem, afm and lm examination. How to turn small mobile devices into hacking secure. An ultramicrotome is used to produce ultrathin sections 60200 nm thick for the purposes of imaginganalysis in the transmission electron microscope. Leica em uc7 ultramicrotome products leica microsystems. Avoiding the artifactcausing conditions of manual sectioning and.

Service is free of charge to all nichd investigators and, resources allowing, to anyone within the porter neurosciences building. The ultramicrotome leica em uc7 provides easy preparation of semi and ultrathin sections as well as perfect, smooth surfaces of biological. Leica em uc7 ultramicrotome with antivibratome table microtome for sale. Leica ultramicrotome em uc7 ntome ultramicrotome for perfect sectioning at room temperature and cryocondition. Leica ultracut uct ultramicrotome cornell center for. The user can walk away from the instrument during trimming. Ultramicrotome for perfect sectioning at room temperature and cryo.

User or sample profile page 37 operating manual leica em fc7 0110. The customer must check the condition of the system upon delivery and file a damage report with the shipping company if the equipment is. Tissue blocks were sectioned with a leica em uc7 ultramicrotome leica, heerbrugg, switzerland equipped with a glass knife to reveal the underlying tissue and trimmed with an. This user manual describes commissioning of the leica em uc7 ultramicrotome, phased testing and adjustment of all components and movement sequences, and restoring the basic functionality. The leica em uc7 provides easy preparation of semi and ultrathin sections as well as perfect, smooth surfaces of biological and industrial samples for tem, sem, afm and lm examination. Ultramicrotome for sectioning at room temperature and cryo leica em uc7 with cryochamber leica em fc7. Sectioning of aluminum with ultramicrotome leica em uc7 youtube. Ultramicrotome ultracut em uc7 leica ultramicrotome for tem room temperature sectioning 10. To achieve this advantage, the artos 3d ultramicrotome automates the process of making high quality, ultrathin 20 nm sections. The leica em uc7 offers advanced ultramicrotome technology and features a touch screen control panel.

How to turn small mobile devices into hacking free download as powerpoint presentation. The ultramicrotome leica em uc7 provides easy preparation of semi and ultrathin. Within minutes the leica em uc7 can be equipped with the leica em fc7 low temperature sectioning system, which incorporates many features and offers a wide range of user bene. More workspace on your table ioniser and em fc7 control is integrated into the leica em uc7 unit no additional controller is necessary knife use information dividing the diamond knife into segments with the 10. Powertome pc ultramicrotome all control functions are activated by touching the control monitor screen, or by mouse, or by using the digital controller. Leica em uc6 ultramicrotome for sale, absolutely likenew condition, barely used. Spin coater spin coater with 100 programmable settings. Sections were stained with uranyl acetate and lead citrate and subsequently examined with a.

Duffield hall 231 safety and training information used to prepare freestanding thin sections of soft materials and biosystems for microscopic examinations or to polish the materials for surfacepro. High vacuum sputter coater for highest resolution fesem analysis leica em scd500. Sample preparation of electron transparent samples for tem analysis can be fabricated using a leica em uc7 ultramicrotome, tripod polisher, or mechanical thinning and ion milling. Forewordthis technical documentation is intended to provide essential informationabout the proper operation and servicing of the leica em uc7ultramicrotome.

Electron and optical microscopy cornell center for. Artos 3d ultramicrotome equipped with the em fc7 cryochamber. Electron microscope core equipment kentucky biomedical. April 10 marc rabinowitz southeast pathology instrument service. Leica uct ultramicrotome for sale, complete, in excellent functional and cosmetic condition, ready for lab user operation.

Leica optics diamond knives for sectioning and block facing quick change from conventional to cryo mode touch pad control center. Ultramicrotome, phased testing and adjustment of all components and movement sequences, and restoring the basic functionality. The automation eliminates several of the manual work steps required by more conventional ultramicrotomes, such as the em uc7 also from leica microsystems. The ultramicrotome leica em uc7 provides easy preparation of semi and ultrathin sections as well as perfect, smooth surfaces of biological and industrial samples for tem, sem, afm and lm examination. Highest quality sectioning leica design by werner holbl. Used leica emuc6 ultramicrotome microtome for sale dotmed. The microtome is used for preparing samples for transmission electron microscopy tem and atomic force microscopy afm. New standard in ultramicrotomy combining ergonomic design and innovative technology the ultramicrotome leica em uc7 sets new standards in ultramicrotomy. Ultramicrotomes are used to prepare semi and ultrathin sections of biological samples thickness ranging between 50200 nm that can be examined under the electron microscope. Equipment baylor sciences building baylor university. Rmcs powertome pc computer controlled ultramicrotome is supplied complete with allinone slim design computer with integrated touch screen control monitor, wireless mouse and keyboard, interconnect cables and accessories. User friendly electron microscope that can be used in a lighted room. The sections are approximately 60 to 100 nanometers in thickness and 0.

View and download leica em fc7 operating manual online. We expect that the versatility of the system will be of great benefit to members of our user community interested in. Welcome and thank you for taking time to visit our website. Refurbished and used leica ultracut s ultramicrotome for sale. Leica em uc7 fc7 brochure v201602 screen en pdf, 2 mb. Leica em fc7 mounted on ultracut uc7 with advanced touch screen control unit instrument function operation of the em fc7 is performed via the control unit. Leica em uc7 fc7 brochure v201602 screen en pdf, 2 mb leica em uc7 fc7 brochure cn pdf, 2 mb leica emuc7 fc7 brochure ru pdf, 985 kb leica em uc7 fc7 brochure jp. The mic is staffed by research scientists with expertise in transmission electron microscopy, scanning electron microscopy, light microscopy, and supporting instruments therein.